HLR3800 Series Potential Relays are used for assisting in the initial function of capacitor start, induction run and capacitor start, capacitor run motors.
The motors are the larger sized compressor motors for residential central air conditioning systems and larger pump motors.
Approved By UL,CUL,TUV,CE,CCC,Rohs. UL File Number: E251539
|
1 、Application
|
Potential Relays
|
| 1) HLR3800 series potential relays are used on motor starts for air conditioner at HVAC system |
| 2) Used on larger commercial applications and air conditioning |
| 3) Also used for submersible pumps, floor cleaning and other applications requiring high starting torque for motors from 1/2Hp to about 5Hp |
|
2 、Ordering information
|
|
HL
|
R
|
3800
|
-
|
3
|
G
|
3
|
D
|
|
Hongli Electric
|
Relay
|
Type
|
Packaging
|
Coil Number
|
Operating characteristics
|
Operating Position
|
Terminal configuration
|
|
3800
|
"Y" :Individual Box Pack
|
3
|
3
|
D
|
|
"-" :Factory Bulk Pack
|
(P.U & D.O)
|
|
|
Product Feature
|
Detailed Product Description
|
• SPNC switching configurations
|
|
• Class B insulation system
|
|
• .250” QC or 8-32 screw terminals
|
|
• TAB mounting or Panel mounting
|
|
• Silver Cadmium Oxide contacts provide long electrical endurance.
|
|
• Contact Rating
|
| |
35A (break only) 277 VAC,cosφ =0.5 |
| 16A (make & break) 277 VAC,cosφ =0.85 |
| • Mechanical Life Expectancy |
1,000,000 operations |
| • Electrical Life Expectancy |
250,000 cycles breaking rated load |
|
|
Technology Data
|
|
Part No.
|
Continuous Coil
Voltage (V)
|
Pick-up (V)
|
Drop-out (V)
Max.
|
|
Min.
|
Max.
|
|
HLR3800-7AD3D
|
168
|
140
|
153
|
45
|
|
HLR3800-5AN3D
|
395
|
262
|
290
|
140
|
|
HLR3800-2AF3D
|
332
|
171
|
184
|
90
|
|
HLR3800-5AI3D
|
395
|
204
|
233
|
130
|
|
HLR3800-4AP3D
|
420
|
300
|
328
|
121
|
|
HLR3800-6AQ3D
|
502
|
314
|
342
|
135
|
|
HLR3800-3AG3D
|
375
|
180
|
195
|
105
|
|
|
|
|
Specification
|
|
HLR3800 Series Potential RelayDownLoad PDF DataSheet
|
|