1. Applicable Scope
HLC-1NH02AAC(1P/30A/480VAC)Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 30A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.
|
2.Type and Meaning |
HL |
C |
- |
1N |
H |
02 |
AA |
C |
HONGLI |
Contactor |
Bulk Pack |
1 Pole |
480 VAC |
30 FLA |
#10-32 Combo screw with quad QC |
with Cover |
|
Product Explanation And Main Technical Parameter |
Type |
HLC-1NH02AAC(1P/30A/380-480VAC) Definite Purpose Contactor |
Standard |
IEC60947
|
UL508
|
Rating of Current |
Ie 30A |
FLA: 30A |
Rating of Contacts Voltage |
Ue 240/277V |
240/277/480/600VAC |
Rating of Insulation Voltage |
Ui 660V |
600V |
Rating of Coil Voltage |
Us 380-480V |
Us: 480VAC 60Hz |
Mechanical Life |
1000,000 Cycle |
1000,000 Cycle |
Electricity life |
100,000 Cycle |
250,000 Cycle |
Product Explanation |
1.Product Description
HLC-1NH02AAC Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 277v, Fixed Operating Current To 30A Single-Phase Load Circuit Control,At Present, Widely Applies To The Single-Phase Mechanical Device Main Circuit As Well As The Single-Phase Air-Conditioner Compressor Control.
2 .The Regular Service Conditon And Installs The Condition
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets
Down The Limiting Value Is -25
b. The Installation Site Elevation Does Not Surpass 2000m
c. The Air Pollution Rank Is 2 Levels
d. Installs The Category Is Ii ;
e. Installment Facing The Gradient Does Not Surpass ±5°
f. Not Remarkable Undulation, Impact And Vibration Place.
3 .Main Technical Parameter
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably
Working, Its Drop Out Voltage In 20% ~ 70%Us
b. Contactor Use Category: Ac-1Ac8a
c. Contactor In With 0.4m Place, Its Noise Below 40db.
4 . Installing Specification And Install Size
a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°
b. Before The Use Should Inspect The Power Terminal And The Contactor
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating
The Breakdown, Behind Check Off May Electrify Tries .
|
|
Conforms To The Standard |
|
1 Conforms To UL508, IEC60947, GB14048 Standard |
2 Approved By UL,CUL,TUV,CE,CCC,Safe Certification and ISO9001 Certification(SGS) |
CCC Certificate Number: 2005010309156761
UL Files Number: E251539
|
|
Ordering Request |
In Order To Guarantee You Purchase Right, Please Read The Specify Type Before Order.
If You Request As Follows: Nominal Current: 30A, Working Voltage: 240/277V,480V,600V, Pole Number: One Pole Without Shunt, Coil Control Voltage: 480V, Wiring Way: Quick Connect, Load Current: Single-Phase Motor Controls Or Heating Load, Packing: 50/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type : HLC-1NH02AAC
Ie |
Pole |
Rating of Coil Control Voltage |
Motor Power |
24VAC |
120VAC |
208/240VAC |
277VAC |
480VAC |
240VAC |
30A |
1P |
HLC-1NQ02AAC |
HLC-1NT02AAC |
HLC-1NU02AAC |
HLC-1NV02AAC |
HLC-1NH02AAC |
1.5Kw |
|