1.Applicable scope & Type description
1 、Applicable scope
HLR3800-3AN5D single-phase motor (compressor) the starting relay mainly uses in exchanging 50/60HZ, the voltage to the 277V control circuit and the nominal current to the 16A power circuit, through starts the electric capacity, the starting single-phase motor (compressor). Is suitable in the air conditioning, the refrigerator and so on industry machine electric appliance equipment and so on domestic electric appliances and water pump.
|
2 、Type and meaning
|
HLR |
3800 |
- |
3 |
A |
N |
5 |
D |
relay |
serial |
bulk pack |
Coil No. |
60Hz |
Operating characteristics |
Operating Position |
Terminal configuration |
|
2.Product explanation and major technique parameter
|
★ Fixed isolation voltage Ui : 600V |
★ Fixed working voltage Ue : AC 277V |
★ Fixed operating current: Ie=16A , Ith=35A |
★ Normal connection and breaking current: 35A 、Breaking current ability: 96A |
★ Mechanical life> 1,000,000 times |
★ Electricity life> 100,000 times |
★ Coil working voltage scope: 70% ~110%Us |
★ Product coil working voltage Us=AC 170 ~ 502V
|
★ The relay winding (cold clean criticality) can attract reliably in AC 170 ~ 502V gathers, the released voltage is not lower than AC 40V. |
|
3.Conforms To The Standard |
|
1 、Conforms To IEC 60730;GB14048.5,UL508 Standard 。 |
2 、Approved By ISO9001 System Certification(SGS)、 CCC,TUV,CE,UL and Safe Certification |
CCC File Number: 2005010303156716
|
TUV File Number: B 05 06 56608 001
|
UL File Number: E251539
|
CE File Number: N8N 05 06 56608 002
|
|
4.Characteristics
|
Part No. |
Continuous Coil
Voltage (V) |
Pick-up (V) |
Drop-out (V)
Max. |
Min. |
Max. |
HLR3800-7AD3D |
168 |
140 |
153 |
45 |
HLR3800-5AN3D |
395 |
262 |
290 |
140 |
HLR3800-2AF3D |
332 |
171 |
184 |
90 |
HLR3800-5AI3D |
395 |
204 |
233 |
130 |
HLR3800-4AP3D |
420 |
300 |
328 |
121 |
HLR3800-6AQ3D |
502 |
314 |
342 |
135 |
HLR3800-3AG3D |
375 |
180 |
195 |
105 |
|